Ultrasound of the Optical Nerve Sheath Diameter as an Indicator of the Increase of the Intracranial Pressure (ICP) in patients with Traumatic Brain Injury

Volume 5, Issue 5, October 2021     |     PP. 62-78      |     PDF (1298 K)    |     Pub. Date: October 24, 2021
DOI: 10.54647/pmh33133    97 Downloads     5824 Views  

Author(s)

Karen Itzel González-Martínez, Department of Emergency Medicine, General Hospital of Mexicalli, Autonomous University of Baja California, Baja California, Mexico
Aldo Giovanni Cerón-Solano, Department of General Surgery, General Hospital of Cuautitlan, Autonomous University of the State of Mexico, Mexico
David Rafael Cañez-Martínez, Department of Anesthesiologist, General Hospital of Mexicalli, Autonomous University of Baja California, Baja California, Mexico
Francisco Javier López-Parra, Department of Emergency Medicine, General Hospital of Mexicalli, Autonomous University of Baja California, Baja California, Mexico
Luis Eduardo Bejarano-López, Department of Emergency Medicine, General Hospital of Mexicalli, Autonomous University of Baja California, Baja California, Mexico

Abstract
Ultrasound at the bedside has gained popularity in more emergency departments and has been integrated as a central element in the training of residents. The Ocular Ultrasound was used for the detection of the Optical Nerve Sheath Diameter in the Ocular Trauma, Retinal Detachment , Intracranial Pressure and Vitreal Hemorrhage . The Ultrasound of the Optical Nerve Sheath Diameter measurement has been validated as an indirect evaluation of Intracranial Pressure. Objective To assess the quality of the ultrasound in patients with Moderate to Severe Craneoencephalic Traumatism as an Indicator of the Increase in Intracranial Pressure in the Emergency Service of the General Hospital of Mexicali. Material and methods. Prior authorization from the Research Ethics Committee, this analytical prospective study was conducted in the emergency service of the General Hospital of Mexicali, from August 2017 to December 2018, where 43 patients with moderate and severe trauma according to the Glasgow scale were received. who underwent ultrasound of the optic nerve sheath (US DVNO) upon admission, recorded the measurement and compared with the results obtained in the tomography, Glasgow and the patient's clinical status, for the diagnosis of intracranial hypertension. Results. The 43 patients with moderate and severe TBI who underwent US DVNO, 10 patients presented DVNO ≥5 mm and 33 DVNO <5 mm, of those who had DVNO ≥ 5 mm, 10 of 10 had tomographic findings of cerebral edema, and 9-10 required hospitalization , craniectomy and / or admission to ICU, those with DVNO <5 mm, 7 of 33 had tomographic findings of edema and in 26 of 33 no findings were found and only 3 required hospitalization. The probability of having cerebral edema with DVNO ≥ 5 mm is 10 to 0 (10: 0), and the probability of requiring hospitalization , craniectomy and / orICU was 9 to 1 (9:1), while the probability of having cerebral edema with DVNO <5 mm 7 to 26, 7 out of 26 or 1 in 3.7 patients and the probability of hospitalization , craniectomy and / or ICU was 3 to 30, that is, 3 out of 30 patients or 1 in each 10. DVNO ≥ 5 mm is associated with hospitalization with error less than 1%. Conclusions The US DVNO is a useful tool in the emergency department as an indicator of increased intracranial pressure in patients with traumatic brain injury, it is considered an effective, non-invasive, simple and reproducible method that can be performed at the patient's bedside and that allows us to an adequate diagnosis and treatment without delay having a positive impact on the patient's morbidity.

Keywords
Ultrasound (US), Diameter of the Optical Nerve Sheath (DVNO), Intracranial Hypertension (ICH), Intracranial pressure (ICP), Traumatic brain injury (TBI).

Cite this paper
Karen Itzel González-Martínez, Aldo Giovanni Cerón-Solano, David Rafael Cañez-Martínez, Francisco Javier López-Parra, Luis Eduardo Bejarano-López, Ultrasound of the Optical Nerve Sheath Diameter as an Indicator of the Increase of the Intracranial Pressure (ICP) in patients with Traumatic Brain Injury , SCIREA Journal of Health. Volume 5, Issue 5, October 2021 | PP. 62-78. 10.54647/pmh33133

References

[ 1 ] ErdalKomut, MD, NalanKozaci, PhD, MD, BedriyeMügeSönmez, MD, FevziYilmaz, MD, SevalKomut, MD, ZelihaNilgünYildirim, MD, İnanBeydilli, MD, CihatYel, MD. Bedside sonographic measurement of optic nerve sheath diameter as a predictor of intracranial pressure in ED. American Journal of Emergency Medicine. 34 (2016); 963-967.
[ 2 ] HizirKazdal, AyhanKanat, HuseyinFindik, Ahmet Sen, Bulent Ozdemir, Osman ErsegunBatcik, OzcanYavasi, Mehmet FatihInecikli. Transorbital Ultrasonographic Measurement of Optic Nerve Sheath Diameter for Intracranial Midline Shift in Patients with Head Trauma. World Neurosurg. (2016) 85: 292-297.
[ 3 ] Dr. Martín de Jesús Sánchez-Zúñiga. Tratamiento de la hipertensión endocraneana.Paciente en estado crítico. Vol. 30. Supl. 1, Abril-Junio 2007. pp. S346-S351.
[ 4 ] Shigemori M, Abe T, Aruga T, Ogawa T, Okudera H, Ono J, et al. Guidelines for the management of severe head injury. 2nd edition. Guidelines from the Guidelines Committee on the Management of Severe Head Injury, the Japan Society of Neurotraumatology. Neurol Med Chir (Tokyo). 2012; 52:1-30.
[ 5 ] Part I. Guidelines for the management of severe traumatic brain injury. In: Management and prognosis of severe traumatic brain injury. (2) Update notice. Guidelines for the management of severe traumatic brain injury: cerebral perfusion pressure.
[ 6 ] Dr. Raúl Carrillo-Esper, Dr. José Martín Meza-Márquez. Trauma craneoencefálico.Vol. 38. Supl. 3 Octubre-Diciembre 2015. pp. S433-S434.
[ 7 ] Scott A. Marshall, MD, Atul Kalanuria, MD, Manjunath Markandaya, MBBS, Paul A. Nyquist, MD, MPH. Management of intracraneal Pressure in the Neurosciences Critical Care Unit. Neurosurg Clin N Am 24. (2013). 361-373.
[ 8 ] F. Gilo Arrojo, A. Herrera Muñoz y B. Anciones. Hipertensión intracraneal aguda. Neurología. 2010;25(Supl 1):3-10.
[ 9 ] Patrick Goeres, BS , Frederick A. Zeiler, MD, Bertram Unger, MD, PhD, DimitriosKarakitsos, MD, PhD, DS, Lawrence M. Gillman, MD, MMedEd, FRCSC, FACS. Ultrasound assessment of optic nerve sheath diameter in healthy volunteers. Journal of Critical Care 31 (2016) 168–171.
[ 10 ] GetawWorku Hassen, MD, PHD, Isaac Bruck, MD, PHD, Joseph Donahue, MD, Benjamin Mason, MD, Brett Sweeney, MD, Weafue Saab, MD, Jeremy Weedon, PHD, Neal Patel, MD,Kenneth Perry, MD, RDMS, Hussein Matari, MD, Rajnish Jaiswal, MD, and Hossein Kalantari, MD, MPH. Accuracy Of Optic Nerve Sheath Diameter Measurement By Emergency Physicians Using Bedside Ultrasound. The Journal of Emergency Medicine, Vol. 48, No. 4, pp. 450–457, 2015.
[ 11 ] Aaron Strumwasser, M.D., Rita O. Kwan, M.D., M.P.H., Louise Yeung, M.D., Emily Miraflor, M.D., Alex Ereso, M.D., Frederico Castro-Moure, M.D., Ph.D., Atul Patel, M.D., Javid Sadjadi, M.D., and Gregory P. Victorino, M.D. Sonographic Optic Nerve Sheath Diameter as an Estimate of Intracranial Pressure in Adult Trauma. Journal of Surgical Research 170, 265–271 (2011).
[ 12 ] Afshin AminiMD , Hamid Kariman MD , Ali ArhamiDolatabadi MD , Hamid Reza Hatamabadi MD, HojjatDerakhshanfar MD , Behnam Mansouri MD , Saeed Safari MD , RazieEqtesadi MD. Use of the sonographic diameter of optic nerve sheath to estimate intracranial pressure. American Journal of Emergency Medicine (2013) 31, 236–239.
[ 13 ] Pedro J. Roque MD, Teresa S. Wu MD, Laura Barth MD, Dave DrachmanPhD , Kai-Ning Khor BA, MPH , Frank LoVecchio DO, MPH , Stephan Stapczynski MD. Optic nerve ultrasound for the detection of elevated intracranial pressure in the hypertensive patient. American Journal of Emergency Medicine (2012) 30, 1357–1363.
[ 14 ] Jose E. Irazuzta MD, FCCM, Martha E. Brown MSN, ARNP, Javed Akhtar MD. Bedside Optic Nerve Sheath Diameter Assessment in the Identification of Increased Intracranial Pressure in Suspected Idiopathic Intracranial Hypertension. Pediatric Neurology 54 (2016) 35-38.
[ 15 ] Susanne Bolesch, Frederic Von Wegner, Christian Senft, Matthias W. Lorenz. Transcranial Ultrasound to Detect Elevated Intracranial Pressure: Comparison of Septum Pellucidum Undulations and Optic Nerve Sheath Diameter. Ultrasound in Med. & Biol., Vol. 41, No. 5, pp. 1233–1240, 2015.
[ 16 ] Lucas Ochoa-Pérez, Alejandro Cardozo Ocampo. Aplicaciones de la Ultrasonografía en el sistema Nervioso central para neuroanestesia y cuidado neurocritico. Revista Colombiana de anestesiología. Volumen 43, Issue 4, Octubre-Diciembre 2015. pp 314-320.